HIGH TENSION CONVERTER FOR ELETRIC SPARK IGNICION

ACS-TE-C5
For electric spark ignition of gas burners. Voltage 115 or 220V - Power 8 VA - secondary voltage 23 Kv - Scheme of service: Intermittent 33% - Operating temperature of 0 to 60ºC.
Replaces model ACS-TE-21-C4 (stays for replacement) and is no longer recommended for new designs, the Selcon.

See specifications and order codes: 
HIGH TENSION CONVERTER FOR ELETRIC SPARK IGNICION

ACS-TE-C6
For electric spark ignition of gas burners or light liquid fuels. Power 120 or 230V +10% -15 - Power 8 Kvef (26 Kvpp) - 35mA. - Scheme of Service: Intermittent 50% - Operating temperature: 0°C to 60ºC.
Replaces the models ACS-C1-TE, TE-ACS and ACS-C2-C3-TE (remain for replacement) and are no longer recommended for new designs by Selcon.

See specifications and order codes: 
ELECTRODE FOR ELETRIC SPARK IGNICION

SEL-HT-C
Electrode for flame sensor (ionization) or ignition. With or without securing thread, with or without protective cover.
120 mm porcelain and 500 mm free length of the electrode / 50 mm porcelain and 140 mm free length of the electrode.


SEL-HT-E
Sensors and electrodes assembled as required by the client’s drawing or sample – SPECIAL.


See specifications and order codes: 
HIGH TENSION ELETRONIC PORTABLE IGNITOR

ACS-IP
High-Voltage Portable Igniter for Gas Burner Spark Ignition.

See specifications and order codes:

TIMED IGNICION PANEL FOR BURNER

ACS-IT
Ignition panel with timer for burners.


See specifications and order codes: 
IGNICION CABLE

ACS-CB-C1521-O
High-insulation cable for ignition of interconnection of ionization sensor; Neoprene; Operating temperature: up to 130°C.

See specifications and order codes: 
IGNICION CABLE

ACS-CB-C2541
High-insulation cable for ignition of interconnection of ionization sensor; Silicone; Operating temperature: up to 300°C.


See specifications and order codes: 
ELECTRODE CONNECTOR / HIGH TENSION CABLE WITH TOUCH PROTECTION

ACS-CP
Connector for electrode/high voltage cable, with touch protection.
Nitrile (up to 100ºC) or Silicone (up to
200º C).

See specifications and order codes: 

PILOT BURNERS

Reform and Maintenance of Burners Pilots.

Custom. Contact us.

ARTICULATED CONNECTION FOR OPTICAL FLAME SENSOR

ACS-CN-C

This connection is adequate to sensors with or without self checking. It uses a standardized flange as the base, allowing the user to make the counter-flange installation even before receiving the part. It enables to improve, during the start-up and any time later, the sensor view of the flame and provides an input for cleaning/cooling air connection. It is recommended where the flame position, in its point of highest stability of radiation emission, is not 100% known. It may be used with all sensors of SEL-SV line manufactured by Selcon.

See specifications and order codes: 
FIXED CONNECTION FOR OPTICAL FLAME SENSOR

ACS-CN-C3
Fixed connection for flame sensor.
See specifications and order codes: 
STANDARDIZED SIGNAL CONVEYOR (4-20mA)

ACS-CV
It converts the flame signal into the standardized signal of 4-20 mA., for the dynamic signaling of the flame status, from the site/view tube perspective, where the sensor is mounted

See specifications and order codes: 
FLAME PRESENCE SIGNAL CONVEYER

ACS-TX
TRANSMITTER OF FLAME PRESENCE SIGNAL - Allows distant transmission of flame presence signal sent by SEL-SV and SEL-HT line sensors.



See specifications and order codes: 
MONITORING PROGRAMMER FOR PARAMETERS OF THE MCQ SYSTEM

ACS-PG-MCQ
The ACS-PG-MCQ programmer allows supervision of the multifuel/MCQ burner system parameters, together with CHM-F-MCQ flame presence detector relay and SEL-SV-MCQ sensor-transmitter (weatherproof or explosion-proof) making this unit the man-machine interface (MMI) of the MCQ system.

See specifications and order codes: 
CABINET FOR ELETRONIC EQUIPAMENT ASSEMBLY

ACS-CS-C20
Cabinet for electronic equipment assembly.

 
See specifications and order codes: 
CONTROL OR POWER CABLE, TRANSMISSION CABLE FOR FLAME PRESENCE SIGNAL OR CONTROL IN GENERAL

ACS-CB-C3:
Used as power or control cable in general. Operating temperature: up to 75°C.
See specifications and order codes: 

ACS-CB-C4217:
Transmission cable of flame presence signal or for serial communication of MCQ system.
See specifications and order codes: 

ACS-CB-C4517:
Recommended for use as a cable transmitting the signal of presence of flame, serial communication via RS 485 (two pairs of conductors) between the transmitter and sensor-relay flame detector, members of the security system calls, online MCQ.
See specifications and order codes: 
HIGH TENSION CONVERTER FOR ELETRIC SPARK IGNICION 
Remain for replacement and are no longer recommended by Selcon for new projects.

ACS-TE-C1
Electronic ignition transformer for gas or light oil. 115 or 220 VAC, 50 or 60 Hz, 10,000 Vpp, 100VA.

See specifications and order codes: 

ACS-TE-C2
Electronic ignition transformer for gas or light oil. 115 or 220 VAC, 50 or 60 Hz, 10,000 Vpp, 60VA.
See specifications and order codes: 

ACS-TE-C3
High-voltage transformer for gas burner spark ignition. 220 VAC, 50 OR 60 Hz, 10,000 Vpp.
See specifications and order codes: 

ACS-TE
-C4
Electronic ignition transformer for gas or light oil. 115 or 220 VAC, 50 or 60 Hz, 10,000 Vpp, 8VA.
See specifications and order codes: 
base.html
R. Américo Samarone, 502 - 04284-000 - São Paulo - SP - Brasil
Phone number: 55 11 3019-1616 -
selcon@selcon.com.br
direitos

Home Historic • Philosophy • ClientsLinks RepresentativesResearchContact
Products: AccessoriesProgrammersRelays Sensors SLPR Price estimate

Copyright 2008 Selcon - All rights reserved
SELCON Sistemas Eletronicos de Controle Ltda.